KabinPLUS KL Colocation
KabinPLUS KL Series 19" Data Center Collocation Rack Cabinets have been designed to offer a multi-user housing with high flexibility and security in a single robust core construction for data centre collocation environments.
Side Panels: split panels – vertical or horizontal, lockable
Heights (in Rack Units) | Baying | Width | Depths | |
---|---|---|---|---|
42U | 2 x | 1 bay of 20U | 800 mm | 1000/1100/1200 mm |
1 bay of 21U | ||||
3 x | 2 bays of 13U each | 800 mm | 1000/1100/1200 mm | |
1 bay of 14U | ||||
4 x | 3 bays of 10U each | 800 mm | 1000/1100/1200 mm | |
1 bay of 9U | ||||
47U | 2 x | 1 bay of 22U | 800 mm | 1000/1100/1200 mm |
1 bay of 23U | ||||
3 x | 3 bays of 15U each | 800 mm | 1000/1100/1200 mm | |
4 x | 4 bays of 11U each | 800 mm | 1000/1100/1200 mm |

Easy and independently adjustable for each bay, manually transferable with U marking on either sides.

Single front and split rear doors tool-free transferable -ventilated with 85% perforation, opens to 180/270 degrees when bayed or not bayed.

With 6 x knockout cable entry areas aligned on the cable ducts with brushes, also overhead cable management on the top panel as an option.

Heavy duty easy steer levelling feet with castors

Easy baying on the front and back sides.

Full electrical bonding of the rack cabinet, side doors, roof and bottom panels with the reference bonding point

Various lock options with open access connectivity
Conformity
- IEC 61587-1, UL 2416, IEC 60082-2, EIA 310-E, ISO 9227, ASTM B 117 (for mechanical properties)
- IEC 61010-1, IEC 60950-1 (for electrical properties)
Load Carrying Capacity
- 1200 kg static load (according to IEC 61587-1)
- 1500 kg static load (tested for UL 2416)
- 1500 kg dynamic load (tested for UL 1678)

Cable Pathways With Common Ducting
All the cables can be installed in a side common duct with an individual brushed bay access to serve each bay independently by a service providing company and secured by a locking mechanism with upper and lower cable entry points. Four (4) independent Common Ducts (2 x right + 2 x left) are transferable on a single collocation enclosure.
Cable Pathways With Independent Ducting
The cable ducts are designed as independent cable pathways to accommodate cabling for each individual bay separately with upper and lower cable entry points. Each bay has its own brushed individual access to its independent cable duct area. Two (2) Independent Ducts (1 x right + 1 x left) are transferable on a single collocation enclosure.


Toolless mounting of "M" shaped and "A" shaped separators & cable pathways

Plastic finger cable organizer, plastic ring cable organizer, metal ring cable organizer, finger cable duct organizer, vertical cable tray
Locking Mechanisms
For the physical security and monitored access to your critical infrastructure KabinPLUS KD 19" Data Center Rack Cabinets offer various locking mechanisms and open access connectivity. Mechanical and electro-mechanical locking, keypad access, proximity card access, fingerprint, eye retina, or hand geometry biometric access and their combinations are among the available choices.